Steam Sterilizers
This line has been especially designed for use in the fields of pharmaceutical production, quality control or biosafety. The equipment is used to sterilize vials, ampoules and different materials involved in the production of injectable substances or in microbiology.
Chamber
Doors
Control Panel
Heating System
Information Record
Loading System
Accesories
Models
Chamber
Entirely made of stainless steel 316L and calculated according to the Asme code. The inner areas which become in contact with steam have sanitary finish. The whole chamber is thermally insulated.
Doors
Vertical or horizontal airtight sliding doors with silicone gasket. Double-door sterilizers fitted with a safety system which prevents both doors from opening at the same time.
Control Panel
Microprocessed command with industrial PLC and HMI touch screen, compliant with FDA 21 CFR part 11, which guarantees data traceability. There are different access levels through passwords to set the different parameters for each cycle.
Heating System
Designed to work with apyrogenic steam coming from a central line. If this is not a possibility, the equipment can be delivered with their own built-in steam generator. This generator may be heated electrically or by means of industrial steam coming from the plant.
Information Record
An alphanumeric printer prints all process data and variables.
Loading System
Composed of loading trolleys and transfer trolleys to place and transfer the products to be processed in the autoclave. For glass vials or ampoules, trolleys are designed to allow loading of trays and to optimize the useful capacity of the chamber. Every loading system is analyzed and designed based on the different kinds of materials to be processed, this being a key element in the design of an autoclave.
Accesories
BSL2.
Drying of rubber plugs.
Double wall cooling system.
SIP filter.
Steam sampling.
Water saving in the vacuum system.
No Break (UPS).
Ampoules leak test.
Ampoules washing.
Drying of rubber plugs.
Double wall cooling system.
SIP filter.
Steam sampling.
Water saving in the vacuum system.
No Break (UPS).
Ampoules leak test.
Ampoules washing.
Models
Models | Capacity (L) |
---|---|
449 | 144 |
442 | 192 |
559 | 225 |
551 | 250 |
669 | 324 |
669 a | 400 |
666 a | 287 |
662 | 432 |
662 a | 545 |
699 a | 583 |
692 a | 733 |
692 b | 792 |
779 | 441 |
772 | 588 |
889 | 576 |
881 | 640 |
882 | 768 |
999 | 779 |
992 | 1033 |
994 | 2031 |
1120 | 1200 |
1140 | 2400 |
*We manufacture customized chambers for capacity greater than 30,000 L.